4.4.4.4 Pattern copy/delete & Segment insert/delete
Program pattern copy
1 Set object pattern number on D1000
2 Set target pattern number on D1001
3 Set PT COPY TRIGGER('4') on D1003
4 Read D1004 data and then wait until DONE('1')
Program pattern delete
1 Set delete pattern number on D1000
2 Set PT DEL TRIGGER('5') on D1003
3 Read D1004 data and then wait until DONE('1')
Insert segment
1 Set program pattern number on D1000
2 Set insert pattern number on D1002
3 Set Temp. TSP, Humi. TSP and segment time on D1010~D1012
4 Set SEG INSERT TRIGGER('6') on D1003
5 Read D1004 data and then wait until DONE('1')
Delete segment
1 Set program pattern number on D1000
2 Set delete segment number on D1002
3 Set SEG DEL TRIGGER('7') on D1003
4 Read D1004 data and then wait until DONE('1')